SKU: nXE3.02BD

Ashly nXe3.02BD 2-Channel Network Power Amplifier plus OPDante and OPDAC4 Option Cards

$3,939.00

Items Included

Ashly nXe3.02BD 2-Channel Network Power Amplifier plus OPDante and OPDAC4 Option Cards

Item Notes

Condition: Fully Working 5 available
5 available View All
Note: Each item is unique. please check individual listings for details.
Title
Add to cart
Pre-Owned Guarantee 14 Day Return Window

Description

The NXE Series 2-Channel Networkable Multi-Mode Power Amplifier from Ashly comes pre-installed with OPDAC4 internal 4-channel DAC with selectable HPF and OPDante Dante Network Audio Interface cards. The OPDante card enables access to digital audio networks at low latencies (83.3 μs) over fast Ethernet. It can be installed in the rear card slot of nXe series amplifiers. Signal can be routed from other Dante enabled devices by simply connecting a Cat5e or Cat6 cable to the card's primary or secondary (redundant) Ethernet ports. The amplifier is capable of driving 2 Ohms loads at full power and offers a maximum rated output power of 3000W per channel at Low Z mode, 2450W at 70V mode, and 1250W in 100V mode. In addition, the amplifier is suitable for use in performance venues, stadiums, arenas, convention centers as well as schools, store fronts, and places of worship. The multi-mode amplifier features an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply can auto-detect 120 or 240 VAC mains, and a Neutrik powerCON is used for the AC cord. Each channel features a selectable output mode of Low Z, 70V, or 100V, an 80 Hz high-pass filter, input limiter, and input gain settings of 26 dB, 32 dB, 38 dB, or 1.4V. Each channel comes with a remote DC level control. The amplifier comes with Neutrik XLR/TRS combo jack and Euroblock input connectors and Neutrik speakON output connectors. The unit features a front panel power switch and level controls that can be disabled. The LEDs indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. In addition, the power amplifier features an Ethernet control with a real-time clock for event scheduling. Read more

Features

  • Ethernet control using Protea NE software
  • Serial data control by Ashly programmable remotes or third party controllers
  • Aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional AES3 digital audio capability, and Cobranet
  • Real-time clock with event scheduler
  • Assign automatic execution of selected functions and tasks
  • Event scheduler is programmed using PneS software and stored in the amplifier
  • Ashly remote control via iPad app for custom design of secure wireless control over a network
  • Features a switch-mode power supply that automatically detects 120 VAC or 240 VAC operation
  • Selectable outputs on each channel allow you to choose the desired output mode
  • Set the DIP-switch configuration for low impedance (2, 4, and 8 Ohms), or constant voltage (70V or 100V)
  • Ashly EMS (Energy Management System) provides an automatic sleep-mode drawing less than 1W (defeatable)
  • Multiple internal power supplies provide increased channel separation and reliability
  • Selectable 80 Hz hi-pass filter, limiter, and input gain per channel via rear panel
  • Remote DC level control per channel
  • Extensive protection circuitry and continuously variable cooling fans
  • Ethernet port for software control and monitoring of amplifier functions with front panel COM activity LED
  • Serial data port available for optional Ashly WR-5 and RD-8C programmable remote controls (optional RS-232 converter INA-1 available for third party controllers)
  • Instant standby mode results in 30% reduction in idle power consumption that is triggered by contact closure, software control, or event scheduler
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Programmable power-on delay
  • Aux preamp line outputs for driving other amplifiers
  • Assignable fault condition logic outputs
  • Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors
  • Neutrik speakON twist locking loudspeaker connectors
  • Neutrik powerCON detachable AC mains connector

Business Financing Options Avaiable

The NXE Series 2-Channel Networkable Multi-Mode Power Amplifier from Ashly comes pre-installed with OPDAC4 internal 4-channel DAC with selectable HPF and OPDante Dante Network Audio Interface cards. The OPDante card enables access to digital audio networks at low latencies (83.3 μs) over fast Ethernet. It can be installed in the rear card slot of nXe series amplifiers. Signal can be routed from other Dante enabled devices by simply connecting a Cat5e or Cat6 cable to the card's primary or secondary (redundant) Ethernet ports. The amplifier is capable of driving 2 Ohms loads at full power and offers a maximum rated output power of 3000W per channel at Low Z mode, 2450W at 70V mode, and 1250W in 100V mode. In addition, the amplifier is suitable for use in performance venues, stadiums, arenas, convention centers as well as schools, store fronts, and places of worship. The multi-mode amplifier features an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply can auto-detect 120 or 240 VAC mains, and a Neutrik powerCON is used for the AC cord. Each channel features a selectable output mode of Low Z, 70V, or 100V, an 80 Hz high-pass filter, input limiter, and input gain settings of 26 dB, 32 dB, 38 dB, or 1.4V. Each channel comes with a remote DC level control. The amplifier comes with Neutrik XLR/TRS combo jack and Euroblock input connectors and Neutrik speakON output connectors. The unit features a front panel power switch and level controls that can be disabled. The LEDs indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. In addition, the power amplifier features an Ethernet control with a real-time clock for event scheduling. Read more

Features

  • Ethernet control using Protea NE software
  • Serial data control by Ashly programmable remotes or third party controllers
  • Aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional AES3 digital audio capability, and Cobranet
  • Real-time clock with event scheduler
  • Assign automatic execution of selected functions and tasks
  • Event scheduler is programmed using PneS software and stored in the amplifier
  • Ashly remote control via iPad app for custom design of secure wireless control over a network
  • Features a switch-mode power supply that automatically detects 120 VAC or 240 VAC operation
  • Selectable outputs on each channel allow you to choose the desired output mode
  • Set the DIP-switch configuration for low impedance (2, 4, and 8 Ohms), or constant voltage (70V or 100V)
  • Ashly EMS (Energy Management System) provides an automatic sleep-mode drawing less than 1W (defeatable)
  • Multiple internal power supplies provide increased channel separation and reliability
  • Selectable 80 Hz hi-pass filter, limiter, and input gain per channel via rear panel
  • Remote DC level control per channel
  • Extensive protection circuitry and continuously variable cooling fans
  • Ethernet port for software control and monitoring of amplifier functions with front panel COM activity LED
  • Serial data port available for optional Ashly WR-5 and RD-8C programmable remote controls (optional RS-232 converter INA-1 available for third party controllers)
  • Instant standby mode results in 30% reduction in idle power consumption that is triggered by contact closure, software control, or event scheduler
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Programmable power-on delay
  • Aux preamp line outputs for driving other amplifiers
  • Assignable fault condition logic outputs
  • Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors
  • Neutrik speakON twist locking loudspeaker connectors
  • Neutrik powerCON detachable AC mains connector

About the Ashly nXe3.02BD 2-Channel Network Power Amplifier plus OPDante and OPDAC4 Option Cards

The Ashly nXE3.02 is a high-power, two-channel network amplifier engineered for demanding sound reinforcement applications where substantial power and network control are required. Part of the nX Series, this model delivers an impressive 6kW of total power, making it capable of driving low-impedance, high-performance loudspeakers in live sound, touring, and large installed venue applications. It utilizes efficient and robust amplifier technology to provide clean, reliable power with low distortion, ensuring the amplified signal maintains its integrity even at high output levels. The amplifier's design focuses on delivering current to demanding loads with stability and control.

A central feature of the nXE3.02 is its network integration, facilitated by a standard Ethernet port. This connectivity allows the amplifier to be managed and monitored remotely via network software, enabling technicians to adjust parameters, check status, and perform diagnostics from a central location. Real-time monitoring of output level, clipping, temperature, and impedance provides valuable insight into the amplifier's performance and health. Comprehensive protection systems guard against common faults such as thermal overload, short circuits, and excessive current, safeguarding both the amplifier and the connected loudspeakers.

Housed in a substantial rack-mountable chassis with focused thermal management, the nXE3.02 is built for the rigorous demands of professional audio. Its combination of extreme power output, networked intelligence, and robust protection makes it a formidable and reliable component for audio systems where high SPL and dependable operation are non-negotiable requirements.

Key Features

  • Ethernet control using Protea NE software
  • Serial data control by Ashly programmable remotes or third party controllers
  • Aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional AES3 digital audio capability, and Cobranet
  • Real-time clock with event scheduler
  • Assign automatic execution of selected functions and tasks
  • Event scheduler is programmed using PneS software and stored in the amplifier
  • Ashly remote control via iPad app for custom design of secure wireless control over a network
  • Features a switch-mode power supply that automatically detects 120 VAC or 240 VAC operation
  • Selectable outputs on each channel allow you to choose the desired output mode
  • Set the DIP-switch configuration for low impedance (2, 4, and 8 Ohms), or constant voltage (70V or 100V)
  • Ashly EMS (Energy Management System) provides an automatic sleep-mode drawing less than 1W (defeatable)
  • Multiple internal power supplies provide increased channel separation and reliability
  • Selectable 80 Hz hi-pass filter, limiter, and input gain per channel via rear panel
  • Remote DC level control per channel
  • Extensive protection circuitry and continuously variable cooling fans
  • Ethernet port for software control and monitoring of amplifier functions with front panel COM activity LED
  • Serial data port available for optional Ashly WR-5 and RD-8C programmable remote controls (optional RS-232 converter INA-1 available for third party controllers)
  • Instant standby mode results in 30% reduction in idle power consumption that is triggered by contact closure, software control, or event scheduler
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Programmable power-on delay
  • Aux preamp line outputs for driving other amplifiers
  • Assignable fault condition logic outputs
  • Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors
  • Neutrik speakON twist locking loudspeaker connectors
  • Neutrik powerCON detachable AC mains connector

Ashly nXe3.02BD 2-Channel Network Power Amplifier plus OPDante and OPDAC4 Option Cards Specs

Power Output
Channels
2
Total Output Power
6kW
Amplifier Topology
High-Efficiency Class D/H
Network Features
Control & Monitoring
Ethernet
Remote Access
Yes
Status Indicators
Level, Clip, Thermal, Impedance
Protection Systems
Fault Protection
Thermal, Short Circuit, Current Limit
Physical Build
Cooling System
High-Flow Fan
Rack Space
2 U
Connections
Speaker Output
Neutrik speakON
Data Port
RJ45 Ethernet

Key Features

  • Ethernet control using Protea NE software
  • Serial data control by Ashly programmable remotes or third party controllers
  • Aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional AES3 digital audio capability, and Cobranet
  • Real-time clock with event scheduler
  • Assign automatic execution of selected functions and tasks
  • Event scheduler is programmed using PneS software and stored in the amplifier
  • Ashly remote control via iPad app for custom design of secure wireless control over a network
  • Features a switch-mode power supply that automatically detects 120 VAC or 240 VAC operation
  • Selectable outputs on each channel allow you to choose the desired output mode
  • Set the DIP-switch configuration for low impedance (2, 4, and 8 Ohms), or constant voltage (70V or 100V)
  • Ashly EMS (Energy Management System) provides an automatic sleep-mode drawing less than 1W (defeatable)
  • Multiple internal power supplies provide increased channel separation and reliability
  • Selectable 80 Hz hi-pass filter, limiter, and input gain per channel via rear panel
  • Remote DC level control per channel
  • Extensive protection circuitry and continuously variable cooling fans
  • Ethernet port for software control and monitoring of amplifier functions with front panel COM activity LED
  • Serial data port available for optional Ashly WR-5 and RD-8C programmable remote controls (optional RS-232 converter INA-1 available for third party controllers)
  • Instant standby mode results in 30% reduction in idle power consumption that is triggered by contact closure, software control, or event scheduler
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Programmable power-on delay
  • Aux preamp line outputs for driving other amplifiers
  • Assignable fault condition logic outputs
  • Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors
  • Neutrik speakON twist locking loudspeaker connectors
  • Neutrik powerCON detachable AC mains connector