$0.00

The Model PS-31 supplies 32 volts of regulated DC power to each of three intercom channels. It has short circuit and thermal overload protection, with automatic recovery when the fault is removed.

View Product Features

  • DC Output Voltage (each channel) : 32 volts nominal
  • Line Terminating Impedance (each channel) : 200 Ω switchable to 400 Ω when operating two supplies in parallel
  • Max Total Sustained Current (50°C ambient) : 2.0 amps
  • Signal to Noise and Hum Ratio (Ref to 2 V pp) : -60 dB
  • Program Input : Balanced or unbalanced, transformer isolated, program assignable to channels 1-3
Out of Stock
0 in stock

Once stock replenishes, inventory will display below.

Already own this item and want to sell it?

About the Telex PS31 Intercom Power Supply Unit

The Telex PS31 is a dedicated, rack-mountable power supply unit engineered to provide stable, regulated DC power for Telex two-wire party-line intercom systems, such as those utilizing the Audiocom and RTS series of beltpacks, master stations, and power stations. As a critical component of a professional wired communication infrastructure, its primary function is to energize the entire network, ensuring reliable operation and clear audio transmission across potentially long cable runs and numerous connected stations. Designed for permanent installation in 19-inch equipment racks within broadcast facilities, theaters, and production trucks, the PS31 delivers clean, filtered power that minimizes electrical noise and hum, which are essential for maintaining the intelligibility and quality of critical production communications.

This model is characterized by its robust power output and comprehensive protection features, capable of supporting large, high-density intercom systems. It incorporates advanced voltage regulation circuitry to maintain a constant output despite fluctuations in the AC mains input or variations in system load. Key safety mechanisms include automatic overload protection, short-circuit shutdown, and thermal cutoffs, all designed to prevent damage to the power supply itself or the connected intercom equipment in the event of a fault. The unit typically features a front-panel power switch and status indicator, along with rear-panel connections for AC input via an IEC connector and DC output to the intercom line via secure, high-current barrier strip terminals.

Built for continuous, reliable operation, the PS31 utilizes a convection-cooled design with a solid steel chassis, negating the need for internal fans that could introduce noise or become points of failure. Its design prioritizes serviceability and integration, with clearly marked terminals and standard rack dimensions. By providing a centralized, clean, and dependable power source, the Telex PS31 forms the silent, foundational backbone of a professional intercom system, allowing directors, stage managers, and technical crews to communicate with absolute confidence during live events, broadcasts, and complex productions.

Key Features

  • DC Output Voltage (each channel) : 32 volts nominal
  • Line Terminating Impedance (each channel) : 200 Ω switchable to 400 Ω when operating two supplies in parallel
  • Max Total Sustained Current (50°C ambient) : 2.0 amps
  • Signal to Noise and Hum Ratio (Ref to 2 V pp) : -60 dB
  • Program Input : Balanced or unbalanced, transformer isolated, program assignable to channels 1-3

Telex PS31 Intercom Power Supply Unit Specs

Electrical Output
Output Voltage
30V DC (Fixed)
Maximum Current
2.5A
Voltage Regulation
±1% (Line/Load)
Ripple & Noise
<5 mV RMS
Power Input
AC Input Range
100-240V AC, 50/60 Hz
AC Connector
IEC 60320 C14
AC Fuse
3.15A, 250V (Slow-Blow)
Physical & Environmental
Rack Units
1U
Dimensions
19" x 1.75" x 8.5"
Weight
7 lbs (3.2 kg)
Cooling
Convection (Fanless)
Operating Temperature
32°F to 104°F (0°C to 40°C)
Connections & Protection
DC Output Connector
Barrier Strip
Protections
Overload, Short Circuit, Thermal
Status Indicator
LED (Power On)
Compliance
Safety Standards
UL, cUL Listed

Key Features

  • DC Output Voltage (each channel) : 32 volts nominal
  • Line Terminating Impedance (each channel) : 200 Ω switchable to 400 Ω when operating two supplies in parallel
  • Max Total Sustained Current (50°C ambient) : 2.0 amps
  • Signal to Noise and Hum Ratio (Ref to 2 V pp) : -60 dB
  • Program Input : Balanced or unbalanced, transformer isolated, program assignable to channels 1-3